18. Remove the bleed screw from the water pump; then
after coolant has drained, apply compressed air to the
bleed opening to purge the remaining coolant from
the system. Install the bleed screw and radiator drain
plug and tighten securely.
! WARNING
Always wear safety glasses when using compressed
air.
19. Remove the coolant hoses from the upper engine
coolant outlet pipes; then remove the lower coolant
hose from the water pump.
40
GZ086A
20. Remove the flange nuts from the front and rear
engine through-bolts; then rock the engine slightly to
relieve engine mount pressure and remove the
through-bolts.
GZ009A
GZ028
GZ369A
GZ008
GZ118
GZ104