Arctic Cat 1000 XT 2014 Service Manual page 117

Table of Contents

Advertisement

Problem: Battery discharges too rapidly
Condition
1. Charging system not charging
2. Cell plates overcharged - damaged
3. Battery short-circuited
4. Electrolyte contaminated
Problem: Battery polarity reversed
Condition
1. Battery incorrectly connected
Remedy
1. Check magneto - regulator/rectifier - circuit connections
2. Replace battery - correct charging system
3. Replace battery
4. Replace battery
Remedy
1. Reverse connections - replace battery - repair damage