Event Logging <Logging - Polycom SoundPoint IP 600 SIP Administrator's Manual

Hide thumbs Also See for SoundPoint IP 600 SIP:
Table of Contents

Advertisement

Administrator Guide - SoundPoint
Attribute
ind.gi.x.y.physX
ind.gi.x.y.physY
ind.gi.x.y.physW
ind.gi.x.y.physH
4.6.1.16 Event Logging <logging/>
Logging parameter changes can impair system operation. Do not change any logging parameters
Warning!
without prior consultation with Polycom.
The event logging system supports the following classes of events:
Level
0
1
2
3
4
5
6
Each event in the log contains the following fields separated by the | character:
• time or time/date stamp
• 1-5 character component identifier (such as "so")
• event class
• cumulative log events missed due to excessive CPU load
• free form text - the event description
94
®
IP SIP
Permitted
Values
Interpretation
IP 500: 0-159
For GraphicIcon type indicators, this is the x-axis loca-
tion of the upper left corner of the indictor measured in
IP 600: 0-319
pixels from left to right.
IP 500: 0-79
For GraphicIcon type indicators, this is the y-axis loca-
tion of the upper left corner of the indicator measured in
IP 600: 0-159
pixels from top to bottom.
IP 500: 1-160
For GraphicIcon type indicators, this is the width of the
indicator measured in pixels.
IP 600: 1-320
IP 500: 1-80
For GraphicIcon type indicators, this is the height of the
indicator measured in pixels.
IP 600: 1-160
Interpretation
Debug only
High detail event class
Moderate detail event class
Low detail event class
Minor error - graceful recovery
Major error - will eventually incapacitate the system
Fatal error
Copyright © 2004 Polycom, Inc.
Optimizing SoundPoint

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SoundPoint IP 600 SIP and is the answer not in the manual?

This manual is also suitable for:

Soundpoint ip 500 sip

Table of Contents