①
Absolute position of the probe in Z direction
②
③
The measured probe center (the machine coordinate)
/
④
The diameter of the probe (the measured value will be shown after calibrating)
⑤
The thickness of the probe
⑥
The measurement feedrate in "JOG" mode (this parameter is used to create the measuring program)
⑦
G17, G18 and G19 for selection
⑧
Spindle speed in r.p.m.
⑨
Direction of rotation of the spindle: M3, M4, or M5
⑩
Safety distance between the measuring surface of the probe and the tool
C a librating the probe
Programming and Operating Manual (Milling)
6FC5398-4DP10-0BA6, 09/2017
1.
Select the machining operating area.
2.
Switch to "JOG" mode.
3.
Open the lower-level menu for tool measurement.
4.
Open the auto tool measurement window.
5.
Press this vertical softkey to enter the probe calibration screen.
6.
You can use this vertical softkey to choose whether to calibrate the tool length and diame-
ter, or to calibrate the tool length only.
7.
Move the tool until it presses down on the measuring surface of the probe. Then the calibra-
tion process is triggered automatically.
N o te:
When calibrating the probe, make sure the tool is approximately aligned with the center of
the measuring surface of the probe.
During the automatic measurement, a dial gauge symbol (
that the measuring process is active.
) displays, which indicates
55