Step
Procedure
5
If the tape test indicates inadequate adhesion, increase the heat setting by 5 degrees, print another
card and try the tape test again.
• Once the temperature has been increased 4 times (20 degrees), reset temperature to default and
increase the Dwell Time by .5 second.
• Repeat this process until adequate adhesion is achieved.
• Ensure that the cards (in use) have a surface roughness (Ra) of 60 micro inches or less.
This information should be available from the card manufacturer.
7
Workbench Printer Utility
See the Workbench Printer Utility Help for additional information.
7.1
Access the Workbench Printer Utility
Click Diagnostics to access the Workbench Printer Utility.
The Workbench Printer Utility displays. Find the Workbench Printer Utility User Guide on your
CD.