The following example illustrates the steps that you should follow to verify a
Dell PowerEdge™ M610 iDRAC6 Update Package:
1 Download the following two files from support.dell.com:
IDRAC_FRMW_LX_2.0.BIN.sign
IDRAC_FRMW_LX_2.0.BIN
2 Import the public key by running the following command line:
gpg --import <linux-security-publickey.txt>
The following output message appears:
gpg: key 23B66A9D: "Dell Computer Corporation
(Linux Systems Group) <linux-
security@dell.com>" not changed
gpg: Total number processed: 1
gpg: unchanged: 1
3 Set the GPG trust level for the Dell public key, if you haven't done so
previously.
Enter the following command:
a
gpg --edit-key 23B66A9D
At the command prompt, enter the following commands:
b
fpr
trust
Enter 5, then press <Enter> to choose I trust ultimately
c
from the menu.
Enter y <Enter> to confirm your choice.
d
Enter quit <Enter> to exit the GPG key editor.
e
This completes validation of the Dell public key.
4 Verify the PowerEdge M610 iDRAC6 package digital signature by running
the following command:
gpg --verify IDRAC_FRMW_LX_2.0.BIN.sign
IDRAC_FRMW_LX_2.0.BIN