Configuring Pef - Dell iDRAC6 User Manual

Remote access controller 6
Hide thumbs Also See for iDRAC6:
Table of Contents

Advertisement

For example, to configure the IPMI privileges to 2 (User), enter the
following command:
racadm config -g cfgIpmiSol -o
cfgIpmiSolMinPrivilege 2
NOTE:
is identical to your managed server's baud rate.
Update the IPMI SOL baud rate using the following command:
b
racadm config -g cfgIpmiSol -o
cfgIpmiSolBaudRate <baud-rate>
where <baud-rate> is 19200, 57600, or 115200 bps.
For example:
racadm config -g cfgIpmiSol -o
cfgIpmiSolBaudRate 57600
Enable SOL by typing the following command at the command prompt.
c
NOTE:
racadm config -g cfgUserAdmin -o
cfgUserAdminSolEnable 1 -i <id>
where <id> is the user's unique ID.

Configuring PEF

You can configure the action you wish iDRAC6 to take for each platform alert.
Table 15-4 lists the possible actions and the value to identify them in RACADM.
Table 15-4. Platform Event Action
Action
No action
Power off
Reboot
Power Cycle
Configure PEF actions using the following command:
254
Using the RACADM Command Line Interface
To redirect the serial console over LAN, ensure that the SOL baud rate
SOL can be enabled or disabled for each individual user.
Value
0
1
2
3