Default
1800
Description
Defines the Telnet idle time-out. This property sets the amount of time in
seconds that a connection is allowed to remain idle (there is no user input).
The session is cancelled if the time limit set by this property is reached.
Changes to this setting do not affect the current session (you must log out
and log in again to make the new settings effective).
An expired Telnet session displays the following error message only after you
press <Enter>:
Warning: Session no longer valid, may have timed out
After the message appears, the system returns you to the shell that generated
the Telnet session.

cfgSerial

This group contains configuration parameters for iDRAC6 services.
One instance of the group is allowed. The following subsections describe the
objects in this group.
cfgSerialSshEnable (Read/Write)
Legal Values
1 (TRUE)
0 (FALSE)
Default
1
Description
Enables or disables the secure shell (SSH) interface on iDRAC6.