Checking the Server Status Screen for Error Messages

When a flashing amber LED is lit, and a particular server has an error,
the main Server Status Screen on the LCD will highlight the affected server
in orange. Use the LCD navigation buttons to highlight the affected server,
then click the center button. Error and warning messages will be displayed on the
second line. The following table lists all of the error messages and their severity.
Table 20-8. Server Status Screen
Severity
Warning
Critical
Critical
316
Recovering and Troubleshooting the Managed System
Description
Creates a compressed .zip file that contains all boot capture
images of the current sequence. The user must have
administrator privileges to perform this action.
Takes you to previous screen, if any, in the replay console.
Starts the screenplay from current screen in the replay console.
Pauses the screenplay on the current screen being displayed in
the replay console.
Stops the screenplay and loads the first screen of that boot
sequence.
Takes you to next screen, if any, in the replay console.
Prints the Boot Capture image that appears on the screen.
Reloads the Boot Capture screen.
Message
System Board Ambient Temp:
Temperature sensor for System
Board, warning event
System Board Ambient Temp:
Temperature sensor for System
Board, failure event
System Board CMOS Battery:
Battery sensor for System Board,
failed was asserted
Cause
Server ambient temperature
crossed a warning threshold
Server ambient temperature
crossed a failure threshold
CMOS battery is not present or
has no voltage