Table 11-1. Serial Over LAN Configuration Settings
Setting
Enable Serial
Over LAN
Baud Rate
Channel
Privilege Level
Limit
Table 11-2. Serial Over LAN Configuration Buttons
Button
Print
Refresh
Advanced
Settings
Apply
6 Change the configuration on the Serial Over LAN Configuration
Advanced Settings screen, if necessary. Dell recommends using the default
values. Advanced Settings allows you to adjust SOL performance by
changing the Character Accumulate Interval and Character Send
Threshold values. For optimal performance, use the default settings of 10
milliseconds and 255 characters respectively.
Ensure that the SOL baud rate is identical to the Failsafe Baud Rate
Description
When selected, the checkbox indicates that Serial Over LAN is
enabled.
Indicates the data speed. Select a data speed of 9600 bps, 19.2
kbps, 57.6 kbps, or 115.2 kbps.
Select a privilege level limit for Serial Over LAN.
Description
Prints the Serial Over LAN configuration values that appear on
the screen.
Reloads the Serial Over LAN screen.
Opens the Serial Over LAN Configuration Advanced Settings
screen.
Applies any new settings that you make while viewing the Serial
Over LAN screen.
Configuring and Using Serial Over LAN