Table 20-8. Server Status Screen (continued)
Severity
Critical
Critical
Critical
Critical
Critical
Warning
Warning
Critical
Critical
Critical
Message
Mem Overtemp: Memory sensor,
correctable ECC <DIMM
Location> was asserted
Mem Fatal SB CRC: Memory
sensor, uncorrectable ECC
was asserted
Mem Fatal NB CRC: Memory
sensor, uncorrectable ECC
was asserted
WatchDog Timer: Watchdog
sensor, reboot was asserted
WatchDog Timer: Watchdog
sensor, timer expired was asserted
Link Tuning: Version Change
sensor, successful software or
F/W change was deasserted
Link Tuning: Version Change
sensor, successful hardware
change <device slot number>
was deasserted
LinkT/FlexAddr: Link Tuning
sensor, failed to program virtual
MAC address (Bus # Device #
Function #) was asserted
LinkT/FlexAddr: Link Tuning
sensor, device option ROM failed
to support link tuning or flex
address (Mezz <location>)
was asserted
LinkT/FlexAddr: Link Tuning
sensor, failed to get link tuning or
flex address data from
BMC/iDRAC6 was asserted
Recovering and Troubleshooting the Managed System
Cause
Memory module overheating
South bridge memory failed
North bridge memory failed
Watch dog timer caused
system to reboot
Watch dog timer expired but
no action taken
Failed to update link tuning
setting for proper NIC operation
Failed to update link tuning
setting for proper NIC operation
FlexAddress could not be
programmed for this device
Option ROM does not support
FlexAddress or linking tuning
Failed to obtain linking tuning
or FlexAddress information
from BMC/iDRAC6