Using the Web Interface
1 Log in to iDRAC6 Web interface.
2 In the system tree, select System.
3 Click the Power Management tab, and then click Power Budget.
The Power Budget screen appears.
4 Click Power Budget Threshold.
NOTE:
Power budget threshold is read-only and cannot be enabled or configured
in iDRAC6.
The Power Budget Threshold table displays the power limit information for
the system:
Enabled indicates whether the system enforces the power budget threshold.
Threshold in Watts and Threshold in BTU/hr display the limit in AC
Watts and BTU/hr respectively.
Threshold in Percentage(of Maximum) displays the percentage of power
capping range.
Using RACADM
On a managed server, open a command line interface and enter:
To view the Power Budget Threshold data from local RACADM, enter the
following commands at a command prompt:
racadm getconfig -g cfgServerPower -o
cfgServerPowerCapWatts
returns <power cap value in AC Watts>
racadm getconfig -g cfgServerPower -o
cfgServerPowerCapBTUhr
returns <power cap value in BTU/hr>
racadm getconfig -g cfgServerPower -o
cfgServerPowerCapPercent
returns <power cap value in %>
NOTE:
For more information about cfgServerPower, including output details,
see "cfgServerPower."