De-Esser Status
Bypass: Turns off the Compressor De-Essing function.
Active: Turns on De-Essing function.
Noise Gate Threshold
Select the Use: radio button to specify the level, up to -50 dB, at which the Noise Gate activates to attenu-
ate input signals that fall below that level.
Noise Gate Depth
Select the Use: radio button to specify the amount, up to -30 dB, of attenuation to apply to the input signal
when the specified Threshold is met.
Compressor Threshold
Select the Use: radio button to specify the ceiling, up to -30 dB, at which the Compressor activates to
attenuate input signals above that level.
Compressor Ratio
Select the Use: radio button to specify the aggressiveness of the compressor, up to 16:1.
De-Esser Threshold
Select the Use: radio button to specify the ceiling, up to -20 dB, at which the De-Esser activates to
attenuate sibilance.
De-Esser Ratio
Select the Use: radio button to specify the aggressiveness of the De-Esser, up to 8:1.
Compressor Mode
No Freeze: The compressor is "free" to operate no matter the input level.
Freeze: Prevents the compressor from "sucking up" room noise during brief pauses in audio input.
Backward Feed Dim Gain
Select the Use: radio button to specify the amount of attenuation, up to -30 dB, will be applied to program
audio being fed back to this source (if it has an associated Backfeed, such as an IFB or Talkback channel).