Field
Data in current interval:
Line Code Violations
Far End Block Error
C-Bit Coding Violation
P-bit Coding Violation
Framing Bit Err
Severely Err Framing Secs
C-bit Err Secs
C-bit Severely Err Secs
P-bit Err Secs
P-bit Severely Err Secs
Unavailable Secs
Line Err Secs
Total Data (last 17 15 minute intervals)
T3 2/0 CT1 1 is up
Frame-format ESF, clock slave,
loopback not set
FDL Performance Report is disabled
Transmitter is sending RAI
Receiver alarm state is LOF
Line loop back activate code using
inband signal last sent
BERT state
Test pattern
Status
Sync Detected
Time
Time past
Bit errors (since test started)
Bits received (since test started)
Bit errors (since latest sync)
Bits received (since latest sync)
Description
Statistics spanning the current 15-minute interval, coving the counts
of these items:
Line code violations: BPV, or EXZ.
Far-end block error.
C-bit coding violation.
P-bit coding violation.
Framing bit error.
C-bit erroneous second.
C-bit severely erroneous second, the second during which 44 C-bit
errors occur.
P-bit erroneous second.
P-bit severely erroneous second, the second during which 44 P-bit
errors occur.
Service unavailable second.
Line erroneous second, during which LOS, BPV, EXZ, C-bit, P-bit,
and other errors occur.
Total data spanning the last 17 intervals.
State of T1 line on the CT3 interface: up or down. In this output
sample, T1 line 1 is up.
Information about the T1 line:
Framing format—ESF or SF.
Clock source—slave for the line clock and master for the internal
clock.
Loopback—Local, remote, payload, or not set.
Transmission of PPR in the FDL is disabled. You can enable that with
the t1 set fdl ansi command.
The transmitter of the T1 line is sending RAI signals. When the T1 line
receives LOS, LOF, or AIS signals, it sends RAI signals.
Type of alarm signal that the T1 line can receive: LOS, LOF, AIS, or
RAI.
The loopback code sent last time is in-band LLB activation request
code.
BERT test state: running, complete, or stopped (not completed).
Test pattern in use, 2^11 in this sample output; synchronization
state, and the number of detected synchronizations.
Duration of the BERT test and time that has elapsed.
Number of bit errors received since start of the BERT test.
Number of bits received since start of the BERT test.
Number of bit errors received since last synchronization.
Number of bits received since last synchronization.
205