Fe1 Unframed; T1-F Interface Configuration Commands; Crc - HP MSR series Command Reference Manual

Hide thumbs Also See for MSR series:
Table of Contents

Advertisement

[Sysname] interface serial 2/0
[Sysname-Serial2/0] fe1 timeslot-list 1,2,5,10-15,18
Related commands

fe1 unframed

fe1 unframed
Use fe1 unframed to configure the E1-F interface to operate in unframed mode.
Use undo fe1 unframed to configure the E1-F interface to operate in framed mode.
Syntax
fe1 unframed
undo fe1 unframed
Default
The E1-F interface operates in framed mode.
Views
E1-F interface view
Default command level
2: System level
Usage guidelines
When the E1-F interface is operating in unframed mode, it is a 2048 kbps interface without timeslot
division and is logically equivalent to a synchronous serial interface.
When it is operating in framed mode, it is physically divided into 32 timeslots numbered 0 through 31,
where timeslot 0 is used for synchronization.
Examples
# Set E1-F interface Serial 2/0 to operate in unframed mode.
<Sysname> system-view
[Sysname] interface serial 2/0
[Sysname-Serial2/0] fe1 unframed
Related commands
fe1 timeslot-list

T1-F interface configuration commands

crc

Use crc to configure CRC mode for a synchronous serial interface formed on a CT1/PRI interface.
Use undo crc to restore the default.
Syntax
crc { 16 | 32 | none }
undo crc