Ring Frequency; Dialling Configuration - Sagem RT3000 User Manual

Gsm/gprs network termination
Table of Contents

Advertisement

The minimum flash
duration. Shorter pulses
may be interpreted as
parts of pulse-dial! (10ms)
The maximum flash
duration. Longer pulses
may be interpreted an
onhook/offhook! (10ms)

16.15 RING frequency

The frequency of the RING signal can be selected between 25Hz and 50Hz.
CHA_HIGH_RING_FREQ defines the RING frequency for the Telephone port.
CHB_HIGH_RING_FREQ defines the RING frequency for the Telephone port.
If the setting is NO, the RING frequency is 25Hz.
Section: RING
Meaning
Ring 50Hz (else 25Hz)
Ring 50Hz (else 25Hz)

16.16 Dialling configuration

Fast Dialling
Normally you must enter the telephone number completely before the SAGEM RT3000
can start dialling. The SAGEM RT3000 starts dialling until you do not press any more
key on the telephone and after the dial timeout is expired - the duration the SAGEM
RT3000 waits for any new key stroke.
If the function Fast Dialling is enabled, the SAGEM RT3000 starts dialling immediately
when you terminate the dial sequence by pressing the Fast Dialling Key: a
For example: 00331234567#.
SAGEM RT3000
Parameters in the file para.ini: advanced configuration
CHB_FLASH_MIN
CHB_FLASH_MAX
Parameter
CHA_HIGH_RING_FREQ YES, NO
CHB_HIGH_RING_FREQ YES, NO
4 - 55
12 - 65
Can be configured by SMS (see page 82)
Can be configured by FTP (see page 83)
Permitted
Values
Can be configured by SMS (see page 82)
Can be configured by FTP (see page 83)
7
50
Factory Setting
NO
NO
#
.
95