Technical Data - Sagem RT3000 User Manual

Gsm/gprs network termination
Table of Contents

Advertisement

Technical data

21 Technical data
Analogue interfaces
Digital interfaces
Supplementary Services
Dialling
Port options
Analogue fax
PC fax
Analogue modem
PC data
PC SMS
Voice codecs
Transmit power
Antenna interface
Power supply
Battery backup
Environment
Compliance
Dimensions
120
2 interfaces RJ11 (a/b-lead), one for analogue telephones, one for
analogue telephones, fax machine, modem.
max. 5 REN for all telecomms equipment connected to the RT3000
USB (Client); RS-232 (ITU V.24/V.28); Data rates: 300 – 115.200 bit/s;
Communication: PC-Fax, PC-SMS, PC-Data (CSD und GPRS)
Call waiting, Call barring, Call forward, CLIP, CLIR, 3-Party-Call,
depending on network
DTMF and Pulse dialling
Polarity Reversal; Billing pulses (12kHz; 16kHz; for Voice calls)
Support of Group 3 Fax machines, 9600 bit/s (V.29)
AT command set TR29 Class 1
Data rates 300,1.200,2.400,4.800,9.600 bit/s (V.21,V.22,V.22bis,V.32)
MNP2 flow control
GPRS:Multislot class 10; class B terminal, coding schemes: CS-1,CS-
2,CS-3,CS-4; PBCCH support
CSD: 300,1.200,2.400,4.800,9.600 bit/s; AT command set ; 9.600 bit/s,
RLP
AT command set; MO/MT/CB
Fullrate,Enhanced Fullrate,Halfrate
EGSM 900 MHz (2 Watt), DCS 1800 MHz (1 Watt),
PCS 1900 MHz (1 Watt)
Impedance: 50 Ohm (nominal); Connector: TNC
Mains: 230 VAC 50Hz or 110 .... 230 VAC 50/60Hz
Input 12 - 24 VDC (Battery backup requires min. 17 VDC)
Regular Autonomy Version:
Battery backup up to 2h operation time / 8h stand-by time
rechargeable
High Autonomy Version:
Battery backup up to 4,5h operation time / 15h stand-by time
rechargeable
Temperature range -10° bis +55° C
Humidity 0-95%, not condensend
CE (Residential, commercial and light-industrial-environment); R&TTE
(GSM); GSM/GPRS-Modul mit GCF-Approval; Safety according to EN
60950
ca.195 x 151 x 38 mm (L x W x H)
ca. 620g (incl. battery and antenna)