16 Parameters in the file para.ini: advanced configuration

The following parameters can be set
by a SMS from a remote location [by SMS] or
by editing the file para.ini that can be downloaded using an FTP program [by FTP]
or
by entering DTMF codes (using a telephone set) [by DTMF] or
by entering AT commands (see AT Command Interface, page 69) [by AT
commands]
So under the heading of the following chapters this is mentioned using the terms "by
SMS", "by FTP", "by DTMF" or "by AT commands".
16.1

Settings for configuration access via DTMF

To configure the SAGEM RT3000 locally by sending DTMF codes from a connected
telephone you need to enter an Access code. This Access code is stored in the
parameter file and can be changed.
Section: DEVICE_ACCESS
Meaning
Access code for DTMF
configuration
16.2

Settings for the configuration access via SMS and FTP

The SAGEM RT3000 must know the remote stations that should be allowed to do
remote service or configuration calls by FTP. For SMS remote configuration you can
configure if the CLIP is checked or not. You can configure up to 5 stations for SMS and
FTP access each. SMS access must also be allowed by setting the parameter
SMS_CONFIG=YES.
SAGEM RT3000
Parameters in the file para.ini: advanced configuration
Parameter
DTMF_PASSWORD
Permitted Values
000000 to 999999 000000
Factory
Setting
85

Hide quick links: