Clip Function Configuration - Sagem RT3000 User Manual

Gsm/gprs network termination
Table of Contents

Advertisement

the tax-pulse level in
range from 0-2,5V
the tax-pulse-
frequency, yes to use
16khz,
no for 12khz
Enable Billing Port B
the tax-pulse duration
in x*10ms
the tax-pulse delay in
x*10ms
the tax-pulse level in
range from 0-2,5V
the tax-pulse-
frequency, yes to use
16khz,
no for 12khz

16.13 CLIP function configuration

When a call comes in and it is ringing the SAGEM RT3000 can transmit the telephone
number of the calling party to the equipment connected to the Telephone port or the
Fax/Modem/Phone port. This function is called CLIP - Calling Line Identification
Presentation.
CHx_CLIP_ENABLED
Section: CLIP
This section includes the parameters for the CLIP function
Meaning
Display CLIP Port A CHA_CLIP_ENABLED
define the delay
between end of first
ring and start of
CID (10ms)
the amount of
seizure bits
SAGEM RT3000
Parameters in the file para.ini: advanced configuration
CHA_PULSE_LEVEL
CHA_16KHZ_BURST
CHB_BILLING_ENABLED
CHB_PULSE_DURATION
CHB_PULSE_DELAY
CHB_PULSE_LEVEL
CHB_16KHZ_BURST
= Yes
Enables the transmission of the CLIP on port x (x=A,
B)
= No
Disables the transmission of the CLIP on port x
(x=A, B)
Parameter
CHA_RING_CLIP_DELAY
CHA_SEIZURE_BITS
0 to 2,5
YES,NO
YES,NO
1 to 100
1 to 60000
0 to 2,5
YES,NO
Can be configured by SMS (see page 82)
Can be configured by FTP (see page 83)
Can be configured by DTMF (see page 80)
Permitted
Values
YES, NO
50 to 200
96 to 300
1
YES
YES
20
100
1
YES
Factory Setting
YES
50
300
93