Configuring An Uplink Policy For The Network-Side Port - HP 6600 Configuration Manual

Table of Contents

Advertisement

Step
2.
Configure one
class for a foreign
CVLAN and
SVLAN pair.
3.
Configure one
SVLAN marking
action for a
CVLAN and
SVLAN pair.
4.
Create a QoS
policy and enter
QoS policy view.
5.
Associate the class
with the behavior.

Configuring an uplink policy for the network-side port

The uplink policy on the network-side port modifies the CVLAN ID of incoming traffic.
To configure an uplink policy for the network-side port:
Step
1.
Enter system view.
2.
Create one class
for a local SVLAN
and foreign
CVLAN pair.
Command
a.
Create a class and enter class view:
traffic classifier tcl-name [ operator
and ]
b.
Specify a foreign CVLAN as a match
criterion:
if-match customer-vlan-id vlan-id
c.
Specify a foreign SVLAN as a match
criterion:
if-match service-vlan-id vlan-id
d.
Return to system view:
quit
a.
Create a traffic behavior and enter
traffic behavior view:
traffic behavior behavior-name
b.
Configure an SVLAN marking action
to replace the foreign SVLAN ID with
a local SVLAN ID:
remark service-vlan-id vlan-id
c.
Return to system view:
quit
qos policy policy-name
classifier tcl-name behavior behavior-name
Command
system-view
a.
Create a class and enter class view:
traffic classifier tcl-name [ operator
and ]
b.
Specify a foreign CVLAN as a match
criterion:
if-match customer-vlan-id vlan-id
c.
Specify a local SVLAN as a match
criterion:
if-match service-vlan-id vlan-id
d.
Return to system view:
quit
193
Remarks
Repeat this step to create one class
for each foreign CVLAN and
SVLAN pair.
Repeat this step to configure one
SVLAN marking action for each
CVLAN and SVLAN pair.
N/A
Repeat this step to create other
class-behavior associations.
Remarks
N/A
Repeat this step to create one class
for each local SVLAN and foreign
CVLAN pair.

Advertisement