Digital and Analog Inputs and Outputs
P270 – Function of Digital Input DI8
Adjustable
Range:
Properties:
Description:
These parameters allow configuring the digital input function, according to the adjustable range listed in
12.6 on page
12-10.
Value
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15...17
18
19
20
21...23
24
25
26
27...31
32
12
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
12-10 | CFW100
0 to 48
cfg
Table 12.6: Digital input functions
Description
Not Used
Run/Stop command
General Enable command
Quick Stop command
Forward Run command
Reverse Run command
Start command
Stop command
Forward Rotation Direction
Local/Remote selection
JOG command
Electronic Potentiometer: Accelerate E.P.
Electronic Potentiometer: Decelerate E.P.
Multispeed reference
2
Ramp selection
nd
Not Used
No External Alarm
No External Fault
Fault Reset
Not Used
Disable Flying Start
Regulates DC link
Locks Setting
Not Used
Multispeed Reference with 2
Ramp
nd
Electronic Potentiometer: Accelerates E.P. with 2
Electronic Potentiometer: Decelerates E.P. with 2
Forward Run with 2
Ramp
nd
Reverse Run with 2
Ramp
nd
Accelerates E.P./Start
Decelerates E.P./ Stop
Stop Command
Safety Switch Command
Function 1 Application
Function 2 Application
Function 3 Application
Function 4 Application
Function 5 Application
Function 6 Application
Function 7 Application
Function 8 Application
(P224 = 1 and P223 = 4) or
(P227 = 1 and P226 = 4)
P221 = 8 or P222 = 8 and P105 = 2
Ramp
P221 = 7 or P222 = 7 and P105 = 2
nd
Ramp
P221 = 7 or P222 = 7 and P105 = 2
nd
P224 = 1 or P227 = 1 and P105 = 2
P224 = 1 or P227 = 1 and P105 = 2
Return
Advance
Factory
P263 = 1
Setting:
P264 = 8
P265 = 0
P266 = 0
P267 = 0
P268 = 0
P269 = 0
P270 = 0
Dependence
--
P224 = 1 or P227 = 1
P224 = 1 or P227 = 1
P224 = 1 or P227 = 1
P224 = 1 or P227 = 1
P224 = 1 or P227 = 1
P224 = 1 or P227 = 1
P223 = 4 or P226 = 4
P220 = 4
P225 = 2 or P228 = 2
P221 = 7 or P222 = 7
P221 = 7 or P222 = 7
P221 = 8 or P222 = 8
P105 = 2
-
-
-
Active fault
-
P320 = 1 or 2
-
-
-
P224 = 1 or P227 = 1
P221 = 7 or P222 = 7
P224 = 1 or P227 = 1
P221 = 7 or P222 = 7
P224 = 1 or P227 = 1
P224 = 1 or P227 = 1
-
-
-
-
-
-
-
-
Table