Fault Auto-Reset - WEG CFW100 Programming Manual

V2.4x
Hide thumbs Also See for CFW100:
Table of Contents

Advertisement

Description:
They indicate the DC link voltage at the moment of the occurred fault.
P053 – Output Frequency Last Fault
Adjustable
0.0 to 300.0 Hz
Range:
Properties:
ro
Description:
They indicate the output frequency at the moment of the occurred fault.
P054 – Temperature in the IGBTs Last Fault
Adjustable
0.0 to 200.0 ºC
Range:
Properties:
ro
Description:
These parameters indicate the IGBTs temperature at the moment of the occurred fault.

13.15 FAULT AUTO-RESET

This function allows the inverter to execute the automatic reset of a fault by means of the setting of P340.
NOTE!
The function auto-reset is locked if the same fault occurs three times in a row within 30 seconds
after the reset.
P340 – Auto-Reset Time
Adjustable
0 to 255 s
Range:
Properties:
Description:
It defines the interval after a fault to activate the inverter auto-reset. If the value of P340 is zero the fault autoreset
function is disabled.
Return
Advance
Faults and Alarms
Factory
Setting:
Factory
Setting:
Factory
0 s
Setting: