3.07 Lift the Power Supply

WARNING
Do not touch live electrical parts.
Disconnect input power conductors from de-energized supply line before moving unit.
FALLING EQUIPMENT can cause serious personal injury and equipment damage.
Use a forklift, crane, or hoist to lift the unit off the shipping pallet as shown. Keep the power supply steady and vertical. Do not
lift it any further than necessary to clear the shipping pallet. Ensure all panels and screws are secure prior to lifting.
Set the power supply on a solid, level surface. The installer may fasten the power supply to the floor or a supporting fixture with
hardware passing through the horizontal parts of the power supply feet.