INSTALLATION

The installation must be executed by a professional.
Note!
Mains supply requirements
High power equipment may, due to the primary current drawn from the mains supply, influence the
power quality of the grid. Therefore connection restrictions or requirements regarding the
maximum permissible mains impedance or the required minimum supply capacity at the interface
point to the public grid may apply for some types of equipment (see technical data). In this case it
is the responsibility of the installer or user of the equipment to ensure, by consultation with the
distrubution network operator if necessary, that the equipment may be connected.
5.1

Location

Position the power source such that its cooling air inlets and outlets are not
obstructed.
5.2

Mains power supply

Check that the welding power source is connected
to the correct voltage and that the correct fuse size
is used. A protective earth connection must be
made in accordance with regulations
5.2.1
Recommended fuse sizes and minimum cable area
Mains voltage
Mains frequency
Mains cable, area
Phase current I
1eff
Welding cable, area
Fuse
anti--surge
type C MCB
NOTE!
The cable area and fuse rating above comply with Swedish regulations. Use the
welding power source in accordance with the relevant national regulations.
bh32d1e
Location of rating plate
Arc 151i
230 V ¦10 %, 1--phase
50--60 Hz
2
3G2.5 mm
11.5 A
2
16 mm
16 A
13 A
- - 20 - -
Arc 201i
230 V ¦10 %, 1--phase
50--60 Hz
2
3G2.5 mm
13.4 A
2
16 mm
16 A
16 A