ESAB 100i Instruction Manual page 86

Plasma systems
Hide thumbs Also See for 100i:
Table of Contents

Advertisement

100i / 200i / 300i / 400i
Inverter 3B Over Temp
264
Ambient
Inverter 1A No Input
265
Power
Inverter 1B No Input
266
Power
Inverter 2A No Input
267
Power
Inverter 2B No Input
268
Power
Inverter 3A No Input
269
Power
Inverter 3B No Input
270
Power
Inverter ID reading
271
fault
Code
Gas Control communication
301/302
or reply fault
Gas Supply Pressure out of
303
range.
304
Gas Control Purging
305
Gas Control protocol error
306
Not used
Gas Control sequencing
307
error
308
Gas Control Type Mismatch
309
Gas Control command fault
310 *
Gas Control Unit fault
Gas Control Unit valve con-
311 *
trol fault
312 *
Gas Selection Console fault
86
CCM Status Code
Group 2 -- Plasma Power Supply
Inverter circuitry is over temperature likely cause is ambient greater than 40 deg
C; Reduce power supply cutting Duty Cycle; Reduce ambient air temperature; Add
auxiliary cooler.
Inverter section may have no input power. Contactor W1 not closed; Defective con-
tactor or CB4 tripped; Inverter section input not connected; Defective Inverter.
Inverter section may have no input power. Contactor W1 not closed; Defective con-
tactor or CB4 tripped; Inverter section input not connected; Defective Inverter.
Inverter section may have no input power. Contactor W1 not closed; Defective con-
tactor or CB4 tripped; Inverter section input not connected; Defective Inverter.
Inverter section may have no input power. Contactor W2 not closed; Defective con-
tactor or CB4 tripped; Inverter section input not connected; Defective Inverter.
Inverter section may have no input power. Contactor W2 not closed; Defective con-
tactor or CB4 tripped; Inverter section input not connected; Defective Inverter.
Inverter section may have no input power. Contactor W2 not closed; Defective con-
tactor or CB4 tripped; Inverter section input not connected; Defective Inverter.
CCM found ID values inconsistant during reading. CCM to an Inverter section rib-
bon damaged or disconnected; Inproper ribbon cable routing.
CCM Status Code
Group 3 -- Gas Controller Status & Protocol
Message
Problem with fiber optic cable to Gas Selection Console or Gas Control Unit;
Dirt on fiber ends or in connectors; blow out with clean dry air. Fiber not
locked into connector; Sharp bends in fiber cable; Fiber defective; Gas Se-
lection Console or Gas Control Unit power supply defective; Gas Selection
Console or Gas Control Unit circuit board defect
Inlet plasma or shield pressure low or defective pressure sensors PS3 & PS4;
For Automatic Gas Control see Gas Control Unit for pressure faults.
Normal following power up or returning from Plasma Disable. Wait for purge
to finish.
Verify Firmware revision for compatibility with Gas Selection Console and Gas
Control Unit.
Reserved for other future use.
Verify Firmware revision for compatibility with Gas Selection Console and Gas
Control Unit
Wrong CCM for Power Supply; Install correct CCM
Verify Firmware revision for compatibility with Gas Selection Console and Gas
Control Unit; Electromagnetic interference with Arc Starter; inspect grounding;
bonding; and isolation
Check Gas Control Unit status indicator for specific problem
Check Gas Control Unit status indicator for specific problem
Check Gas Selection Console status indicator for specific problem
OPERATION
Remedy / Comments
Manual PN: 0560956430

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

200i300i400i