7. Make sure that the hose going to the Gas Selection Console is connected to the port on the WMS Water Softener marked
"OUT" and the incoming water supply connected to the port marked "IN". Do not mount over any electronics or outlets
in case of leaks during operation or spills when changing the element at a later date.

3.18 Gas Control Unit Installation

The Gas Control Unit must be installed in a suitable location close to the Torch such as the gantry. The unit must be mounted
to a flat horizontal surface. If the Module is mounted to any support subject to vibration or motion, the installer must fasten the
module to the support securely.
The Module should be located as far away as possible from the Arc Starter due to possible electromagnetic interference. It is
acceptable to locate the control cable in the same track as the cables from the Arc Starter and away from torch leads.
The Module includes feet which lift the bottom panel off the mounting surface. Louvers on the back panel of the module must
remain unblocked, for the free passage of ventilating air.
The Module also comes with non metallic isolation grommets for mounting. These must be used in all four mounting slots to raise
the Module so there is no metal to metal contact between the Module and the mounting surface in order to reduce the chance of
EMI interference.
Manual PN: 0560956430
INSTALLATION
100i / 200i / 300i / 400i
55