ESAB 100i Instruction Manual page 83

Plasma systems
Hide thumbs Also See for 100i:
Table of Contents

Advertisement

Work Current Too
210
High
Work Current Too
211
Low
Inverter 1A Output
212
Current Low
Inverter 1B Output
213
Current Low
Inverter 2A Output
214
Current Low
Inverter 2B Output
215
Current Low
Inverter 3A Output
216
Current Low
Inverter 3B Output
217
Current Low
Inverter 1A Output
218
Current High
Inverter 1B Output
219
Current High
Inverter 2A Output
220
Current High
Inverter 2B Output
221
Current High
Inverter 3A Output
222
Current High
Inverter 3B Output
223
Current High
224
Inverter 1 Not Found
Inverter 1A Incompat-
225
ible Revision
Inverter 1B Incompat-
226
ible Revision
Inverter 2A Incompat-
227
ible Revision
Inverter 2B Incompat-
228
ible Revision
Inverter 3A Incompat-
229
ible Revision
Manual PN: 0560956430
CCM Status Code
Group 2 -- Plasma Power Supply
Work lead current detected greater than 16% above process setting. Possible defec-
tive HCT1 Work lead current sensor or Relay PCB; Defective CCM.
Work current detected more than 16% below process setting. Possible defective
HCT1 Work lead current sensor or Relay PCB; Possible defective pilot PCB (shorted
IGBT);
Plasma work current low during cutting and attributed to Inverter Module 1 Sec-
tion A output low; Inverter output disconnected; Possible defective ribbon cable; If
problem persists replace Inverter Module 1
Plasma work current low during cutting and attributed to Inverter Module 1 Sec-
tion B output low; Inverter output disconnected; Possible defective ribbon cable; If
problem persists replace Inverter Module 1
Plasma work current low during cutting and attributed to Inverter Module 2 Section
A output low; Inverter output disconnected; Possible defective ribbon cable; If
problem persists replace Inverter Module 2
Plasma work current low during cutting and attributed to Inverter Module 2 Section
B output low; Inverter output disconnected; Possible defective ribbon cable; If
problem persists replace Inverter Module 2
Plasma work current low during cutting and attributed to Inverter Module 3 Section
A output low; Inverter output disconnected; Possible defective ribbon cable; If
problem persists replace Inverter Module 3
Plasma work current low during cutting and attributed to Inverter Module 3 Section
B output low; Inverter output disconnected; Possible defective ribbon cable; If
problem persists replace Inverter Module 2
Plasma work current high during cutting and attributed to Inverter Module 1 Section
A output high; If problem persists replace Inverter Module 1
Plasma work current high during cutting and attributed to Inverter Module 1 Section
B output high; If problem persists replace Inverter Module 1
Plasma work current high during cutting and attributed to Inverter Module 2 Section
A output high; If problem persists replace Inverter Module 2
Plasma work current high during cutting and attributed to Inverter Module 2 Section
B output high; If problem persists replace Inverter Module 2
Plasma work current high during cutting and attributed to Inverter Module 3 Section
A output high; If problem persists replace Inverter Module 3
Plasma work current high during cutting and attributed to Inverter Module 3 Section
B output high; If problem persists replace Inverter Module 3
Inverter Module 1 Section A required for Piloting; Bad ribbon cable connection to
CCM J31 to Inverter Module 1 Section A.
Unsupported Inverter Revision; Ribbon cable CCM J31 to Inverter Module 1 Section
A damaged; CCM code version incompatible with Inverter revision or model
Unsupported Inverter Revision; Ribbon cable CCM J32 to Inverter Module 1 Section
B damaged ; CCM code version incompatible with Inverter revision or model
Unsupported Inverter Revision; Ribbon cable CCM J33 to Inverter Module 2 Section
A damaged; CCM code version incompatible with Inverter revision or model
Unsupported Inverter Revision; Ribbon cable CCM J34 to Inverter Module 2 Section
B damaged; CCM code version incompatible with Inverter revision or model
Unsupported Inverter Revision; Ribbon cable CCM J35 to Inverter Module 3 Section
A damaged; CCM code version incompatible with Inverter revision or model
OPERATION
100i / 200i / 300i / 400i
83

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

200i300i400i

Table of Contents