ESAB 100i Instruction Manual page 84

Plasma systems
Hide thumbs Also See for 100i:
Table of Contents

Advertisement

100i / 200i / 300i / 400i
Inverter 3B Incompat-
230
ible Revision
Inverter 1A VAC
231
Mismatch
Inverter 1B VAC
232
Mismatch
Inverter 2A VAC
233
Mismatch
Inverter 2B VAC
234
Mismatch
Inverter 3A VAC
235
Mismatch
Inverter 3B VAC
236
Mismatch
Too Few Inverters
237
Found
238
BIAS VAC Invalid
239
AC Voltage High
240
AC Voltage Low
Inverter 1A Input Volt-
241
age Error
Inverter 1B Input Volt-
242
age Error
Inverter 2A Input Volt-
243
age Error
Inverter 2B Input Volt-
244
age Error
Inverter 3A Input Volt-
245
age Error
84
CCM Status Code
Group 2 -- Plasma Power Supply
Unsupported Inverter Revision; Ribbon cable CCM J36 to Inverter Module 3 Section
B damaged; CCM code version incompatible with Inverter revision or model
Inverter AC Voltage rating incompatible with Power Supply voltage rating; Bad
ribbon cable connection CCM J31 to Inverter Module 1 Section A; Wrong voltage
Inverter Module 1 installed; Defective Inverter module
Inverter AC Voltage rating incompatible with Power Supply voltage rating; Bad
ribbon cable connection CCM J32 to Inverter Module 1 Section B; Wrong voltage
Inverter Module 1 installed; Defective Inverter module
Inverter AC Voltage rating incompatible with Power Supply voltage rating; Bad
ribbon cable connection CCM J33 to Inverter Module 2 Section A; Wrong voltage
Inverter Module 2 installed; Defective Inverter module
Inverter AC Voltage rating incompatible with Power Supply voltage rating; Bad
ribbon cable connection CCM J34 to Inverter Module 2 Section B; Wrong voltage
Inverter Module 2 installed; Defective Inverter module
Inverter AC Voltage rating incompatible with Power Supply voltage rating; Bad
ribbon cable connection CCM J35 to Inverter Module 3 Section A; Wrong voltage
Inverter Module 3 installed; Defective Inverter module
Inverter AC Voltage rating incompatible with Power Supply voltage rating; Bad
ribbon cable connection CCM J36 to Inverter Module 3 Section B; Wrong voltage
Inverter Module 3 installed; Defective Inverter module
Two or more Inverter Sections required to operate; Ribbon cable from CCM to
Inverter Section damaged or disconnected;
Invalid AC Voltage Selection; Damaged or loose connection at J61 of System Bias
Supply; Defective System Bias PCB
System Bias PCB detected AC Voltage is higher than Power Supply rated Voltage;
System Bias Supply J61 Voltage Selection connection damaged or disconnected;
Defective System Bias PCB; Defective CCM
System Bias PCB detected AC Voltage is lower than Power Supply rated Voltage;
System Bias Supply J61 Voltage Selection connection damaged or disconnected;
Defective System Bias PCB; Defective CCM
Inverter Input Voltage fault; voltage out of range or missing phase at AC Input of In-
verter Module 1 Section A; Poor AC Power Quality; Defective W1 contactor; Loose or
open connection between input terminals and W1 contactor or contactor and input
of Inverter Section; Defective Inverter module
Inverter Input Voltage fault; voltage out of range or missing phase at AC Input of In-
verter Module 1 Section B; Poor AC Power Quality; Defective W1 contactor; Loose or
open connection between input terminals and W1 contactor or contactor and input
of Inverter Section; Defective Inverter module
Inverter Input Voltage fault; voltage out of range or missing phase at AC Input of In-
verter Module 2 Section A; Poor AC Power Quality; Defective W1 contactor; Loose or
open connection between input terminals and W1 contactor or contactor and input
of Inverter Section; Defective Inverter module
Inverter Input Voltage fault; voltage out of range or missing phase at AC Input of In-
verter Module 2 Section B; Poor AC Power Quality; Defective W2 contactor; Loose or
open connection between input terminals and W2 contactor or contactor and input
of Inverter Section; Defective Inverter module
Inverter Input Voltage fault; voltage out of range or missing phase at AC Input of In-
verter Module 3 Section A; Poor AC Power Quality; Defective W2 contactor; Loose or
open connection between input terminals and W2 contactor or contactor and input
of Inverter Section; Defective Inverter module
OPERATION
Manual PN: 0560956430

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

200i300i400i

Table of Contents