Torch Consumables Installation - ESAB 100i Instruction Manual

Plasma systems
Hide thumbs Also See for 100i:
Table of Contents

Advertisement

100i / 200i / 300i / 400i

7.04 Torch Consumables Installation

1. Install the consumables as follows:
Electrode
Plasma Gas
Distributor
Tip
Shield Gas
Distributor
Shield Cap
3: Thread Shield Cup onto Cartridge
2, Remove the Removal Tool from the Cartridge and install the assembled Cartridge onto the Torch Head.
114
Do not install consumables into the Cartridge
while the Cartridge is attached to the Torch Head.
Keep foreign materials out of the consumables and Cartridge.
Handle all parts carefully to avoid damage,
which may affect torch performance.
1: Stack Parts
Upper O-Ring
on Tip
No Gaps
Between Parts
TORCH INFORMATION
WARNINGS
2: Press Cartridge onto Stacked Parts
4: Check Shield Cap Protrusion
Shield Cup
Shield Cap
Shield Cap Protrudes
0.063-0.083" (1.6 - 2.1 mm)
Art # A-03887
Cartridge Covers
Upper O-Ring
on Torch Tip
Art # A-04716_AB
Manual PN: 0560956430