2.04

Power Supply Specifications

2.04.01
3 Phase
60i 208 - 480 VAC 3 Phase Power Supply Specifications
Input Power
3 Phase Input Power Cable
Output Current
Power Supply Gas Filtering
Ability
Maximum Inlet Pressure
60i 400 VAC 3 Phase CE Power Supply Specifications
Input Power
3 Phase Input Power Cable
Output Current
Power Supply Gas Filtering
Ability
Maximum Inlet Pressure
2.04.02
Additional Power Supply Specifications
Ambient Air Temperature
All Units
* NOTE: The duty cycle will be reduced if the primary input power (AC) is low or the output
Recommended
3/4"
16
208 - 480 VAC(187 - 528 VAC), 3 Phase, 50/60 Hz
Power Supply includes 9' three phase 12AWG 4/C input
Power Supply includes 9' three phase 12AWG 4/C input
60i Power Supply Duty Cycle *
Duty Cycle
Current
DC Voltage
voltage (DC) is higher than shown in this chart.
60i Cut Capacity
(19.05mm)
INTRODUCTION
cable without plug.
10 - 60 Amps, Continuously Adjustable
Particulates to 5 Microns
125 PSI (8.6 bar)
400 VAC, 3 Phase, 50/60 Hz
cable with plug.
10 - 60 Amps, Continuously Adjustable
Particulates to 5 Microns
125 PSI (8.6 bar)
Duty Cycle Ratings @ 40° C (104° F)
Operating Range 0° - 50° C
50%
60 Amps
50 Amps
126
Pierce
5/8" (
15.86mm)
Rating
60%
100%
40 Amps
122
119
Maximum
1 1/2" (38mm)
0-5562

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cutmaster 60i

Table of Contents