300i Power Supply: Gas Pressures, Flows, and Quality Requirements
Gas
O
(Oxygen)
2
N
(Nitrogen)
2
Compressed
or Bottled Air
H35 (Argon-Hydrogen)
H35 = 35% Hydrogen,
65% Argon
H
O (Water)
2
Note 1: The air source must be adequately filtered to remove all oil or grease. Oil or grease
contamination from compressed or bottled air can cause fires in conjunction with oxygen.
For filtering, a coalescing filter able to filter to 0.01 microns should be placed as close as
possible to the gas inlets on the Gas Control Module.
Note 2: The tap water source does not need to be deionized, but in water systems with extremely high mineral content
a water softener is recommended. Tap water with high levels of particulate matter must be filtered.
Note 3: Water Pressure Regulator No. 8-6118 is recommended to ensure proper water pressure.
400i Power Supply: Gas Pressures, Flows, and Quality Requirements
Gas
O2 (Oxygen)
N2 (Nitrogen)
Compressed
or Bottled Air
H35 (Argon-Hydrogen)
H35 = 35% Hydrogen,
65% Argon
H17 17.5% Hydrogen
32.5% Argon
50% Nitrogen
Ar (Argon)
H2O (Water)
Note 1: The air source must be adequately filtered to remove all oil or grease. Oil or grease
contamination from compressed or bottled air can cause fires in conjunction with oxygen.
For filtering, a coalescing filter able to filter to 0.01 microns should be placed as close as
possible to the gas inlets on the Gas Control Module.
Note 2: The tap water source does not need to be deionized, but in water systems with extremely high mineral con-
tent a water softener is recommended. Tap water with high levels of particulate matter must be filtered.
Note 3: Water Pressure Regulator No. 8-6118 is recommended to ensure proper water pressure.
Manual PN: 0560956430
Quality
Minimum Pressure
99.5% Purity
(Liquid recommended)
99.5% Purity
(Liquid recommended)
<1000 ppm O
, <32 ppm
2
H
O)
2
Clean, Dry,
Free of Oil (see Note 1)
99.995% Purity
(gas recommended)
See Note 2
Quality
99.5% Purity
(Liquid recommended)
99.5% Purity
(Liquid recommended)
<1000 ppm O2, <32 ppm
H2O)
Clean, Dry,
Free of Oil (see Note 1)
99.995% Purity
(gas recommended)
99.995% Purity
(gas recommended)
99.995% Purity
(gas recommended)
See Note 2
SPECIFICATIONS
120 psi
8.3 bar / 827 kPa
120 psi
8.3 bar / 827 kPa
120 psi
8.3 bar / 827 kPa
120 psi
8.3 bar / 827 kPa
55 psi (3.8 bar)
Minimum Pressure
120 psi
8.3 bar / 827 kPa
120 psi
8.3 bar / 827 kPa
120 psi
8.3 bar / 827 kPa
120 psi
8.3 bar / 827 kPa
120 psi
8.3 bar / 827 kPa
120 psi
8.3 bar / 827 kPa
55 psi (3.8 bar)
100i / 200i / 300i / 400i
Flow
200 scfh (95 lpm)
300 scfh (141.6 lpm)
450 scfh (212.4 lpm)
200 scfh (94.4 lpm)
10 gph (0.6 lpm)
Flow
200 scfh (95 lpm)
300 scfh (141.6 lpm)
500 scfh (236 lpm)
200 scfh (95 lpm)
200 scfh (95 lpm)
150 scfh (70.8 lpm)
10 gph (0.6 lpm)