Command Descriptions
[SOURce[1]]:FREQuency:SPAN
Group
Syntax
Related Commands
Arguments
Returns
Examples
[SOURce[1]]:FREQuency:STARt
Group
Syntax
Related Commands
2-50
This command sets or queries the span of frequency sweep for the specified channel.
This command is always used with the [SOURce[1]]:FREQuency:CENTer
command. The setting range of frequency span depends on the waveform selected
for sweep.
Source
[SOURce[1]]:FREQuency:SPAN
[SOURce[1]]:FREQuency:SPAN
[SOURce[1]]:FREQuency:CENTer,
<frequency>::=<NRf>[<units>]
where:
<NRf> is the frequency span.
<units>::=[Hz | kHz | MHz]
<frequency>
SOURce1:FREQuency:SPAN 900 kHz
sets the CH 1 frequency span to 900 kHz.
This command sets or queries the start frequency of sweep for the specified
channel. This command is always used with the [SOURce[1]]:FREQuency:STOP
command. The setting range of start frequency depends on the waveform selected
for sweep. For more information on the setting range, refer to the specifications
page of Quick Start User Manual.
Source
[SOURce[1]]:FREQuency:STARt
[SOURce[1]]:FREQuency:STARt
[SOURce[1]]:FREQuency:MODE [SOURce[1]]:FREQuency:STOP
AFG2021 Arbitrary Function Generator Programmer Manual
{<frequency>|MINimum|MAXimum}
? {MINimum|MAXimum}
[SOURce[1]]:FREQuency:MODE
{<frequency>|MINimum|MAXimum}
?
{MINimum|MAXimum}