AFG1000 Series
Declassification and Security
Instructions
*P077113600*
077-1136-00

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AFG1000 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Tektronix AFG1000 Series

  • Page 1 AFG1000 Series Declassification and Security Instructions *P077113600* 077-1136-00...
  • Page 2 Tektronix. All rights reserved. Licensed software products are owned by Tektronix or its subsidiaries or suppliers, and are protected by national copyright laws and international treaty provisions. Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supersedes that in all previously published material.
  • Page 3: Table Of Contents

    Memory devices Volatile memory devices ........................ Nonvolatile memory devices ......................Built-in security features Secure ............................. Clear and sanitize procedures Clear Flash procedure ........................Clear or sanitize a non-functional instrument USB Flash drive ..........................Charges ............................AFG1000 Series Declassification and Security...
  • Page 4 Table of Contents AFG1000 Series Declassification and Security...
  • Page 5: Preface

    Preface This document helps customers with data security concerns to sanitize or remove memory devices from the Tektronix AFG1000 Series Arbitrary Function Generators. These products have data storage (memory) devices and data output devices. These instructions tell how to clear or sanitize the memory devices and disable the data output devices.
  • Page 6 Directly. Describes how data is modified. It means that the user can modify ■ the data. Indirectly. Describes how data is modified. It means that the instrument ■ system resources modify the data and that the user cannot modify the data. AFG1000 Series Declassification and Security...
  • Page 7: Memory Devices

    8 x 128 M Type of user information User data, user settings, user waveforms stored User modifiable Data input method Firmware operations Location Process to sanitize Refer to the Clear Flash procedure on page 5 AFG1000 Series Declassification and Security...
  • Page 8 Memory devices Nonvolatile memory devices (cont.) AFG1000 Series Declassification and Security...
  • Page 9: Built-In Security Features

    The AFG3000 Series Arbitrary Function Generators have the following security functions: ■ Secure Secure To erase confidential data from your AFG1000 Series Arbitrary Function Generator, use the Secure function. Clear Flash procedure on page 5 It does the following: ■...
  • Page 10 Built-in security features AFG1000 Series Declassification and Security...
  • Page 11: Clear And Sanitize Procedures

    Use this Secure function to erase confidential data from your instrument. This procedure does not erase or change factory calibration constants. 1. Power on the instrument. 2. Select Arab > others > File_browse. 3. Select Enter. 4. Select Secure. The user waveforms will be erased. AFG1000 Series Declassification and Security...
  • Page 12 Clear and sanitize procedures AFG1000 Series Declassification and Security...
  • Page 13: Clear Or Sanitize A Non-Functional Instrument

    This is the start of your concept. Remove any attached USB flash drives from the instrument before returning the instrument for repair. Charges Replacement of any missing hardware will be charged according to the rate at the time of replacement. AFG1000 Series Declassification and Security...