Arguments
Examples
*SAV (No Query Form)
Group
Syntax
Related Commands
Arguments
Examples
[SOURce[1]]:AM[:DEPTh]
Group
Syntax
AFG2021 Arbitrary Function Generator Programmer Manual
None
*RST
resets the instrument settings to the factory defaults.
This command stores the current settings of the instrument to a specified setup
memory location.
A setup memory location numbered 0 ( last setup memory) is automatically
overwritten by the setups when you power off the instrument.
If a specified numbered setup memory is locked, this command causes an error.
Memory
*SAV
{1|2|3|4}
*RCL
1, 2, 3, or 4 specifies the location of setup memory.
*SAV 2
saves the current instrument state in the memory location 2.
This command sets or queries the modulation depth of AM modulation for the
specified channel. You can set the modulation depth from 0.0% to 120.0% with
resolution of 0.1%.
Source
[SOURce[1]]:AM[:DEPTh]
[SOURce[1]]:AM[:DEPTh]
{<depth>|MINimum|MAXimum}
?
{MINimum|MAXimum}