Outputting System Information To The Trap Buffer - HP A3100-8 v2 EI Configuration Manual

A3100 v2 switch series
Hide thumbs Also See for A3100-8 v2 EI:
Table of Contents

Advertisement

To do...
Name the channel with a specified
channel number
Configure the output rules of the
system information
Specify the source IP address for
the log information
Configure the format of the time
stamp for system information
output to the log host
Set the format of the system
information sent to a log host to
UNICOM
Specify a log host and configure
the related output parameters

Outputting system information to the trap buffer

NOTE:
The trap buffer receives the trap information only, and it discards the log and debugging information even
if you have configured to output them to the trap buffer.
To do...
Enter system view
Enable information center
Use the command...
info-center channel
channel-number name
channel-name
info-center source { module-name |
default } channel { channel-number
| channel-name } [ debug { level
severity | state state } * | log { level
severity | state state } * | trap
{ level severity | state state } * ] *
info-center loghost source
interface-type interface-number
info-center timestamp loghost
{ date | iso | no-year-date |
none }
info-center format unicom
info-center loghost { ipv6
host-ipv6-address |
host-ipv4-address } [ port
port-number ] [ channel
{ channel-number |
channel-name } | facility
local-number ] *
Use the command...
system-view
info-center enable
162
Remarks
Optional
See
Table 5
for default channel
names.
Optional
See
"Default output rules of system
information."
Optional
By default, the source interface is
determined by the matched route,
and the primary IP address of this
interface is the source IP address of
the log information.
Optional
date by default.
Optional
HP by default.
Required
By default, the system does not
output information to a log host. If
you specify to output system
information to a log host, the
system uses channel 2 (loghost) by
default.
The value of the port-number
argument should be the same as
the value configured on the log
host. Otherwise, the log host
cannot receive system information.
Remarks
Optional
Enabled by default

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents