To do...
Enter NQA test group view
Enter test type view of the test
group
Configure the interval for collecting
the statistics of test results
Configure the maximum number of
statistics groups that can be kept
Configure the hold time of statistics
groups
NOTE:
The NQA statistics collection function is not supported in DHCP tests.
If you use the frequency command to set the frequency between two consecutive tests to 0, only one test
is performed, and no statistics group information is collected.

Configuring the history records saving function

The history records saving function enables the system to save the history records of NQA tests. To view
the history records of a test group, use the display nqa history command.
The configuration task also allows you to configure the following elements:
Lifetime of the history records—The records are removed when the lifetime is reached.
The maximum number of history records that can be saved in a test group—If the number of history
records in a test group exceeds the maximum number, the earliest history records are removed.
Follow these steps to configure the history records saving function of an NQA test group:
To do...
Enter system view
Enter NQA test group view
Enter NQA test type view
Enable the saving of the
history records of the NQA
test group
Set the lifetime of the history
records in an NQA test
group
Use the command...
nqa entry admin-name
operation-tag
type { dlsw | dns | ftp | http |
icmp-echo | snmp | tcp |
udp-echo | udp-jitter | voice }
statistics interval interval
statistics max-group number
statistics hold-time hold-time
Use the command...
system-view
nqa entry admin-name operation-tag
type { dhcp | dlsw | dns | ftp | http |
icmp-echo | snmp | tcp | udp-echo |
udp-jitter | voice }
history-record enable
history-record keep-time keep-time
27
Remarks
Optional
60 minutes by default.
Optional
2 by default.
To disable collecting NQA
statistics, set the maximum number
to 0.
Optional
120 minutes by default.
Remarks
Required
By default, history records of the
NQA test group are not saved.
Optional
By default, the history records in
the NQA test group are kept for
120 minutes.

Advertisement