Configuration prerequisites
Voice tests require cooperation between the NQA server and the NQA client. Before you start voice tests,
configure a UDP listening service on the NQA server. For more information about UDP listening service
configuration, see
Configuring voice tests
Follow these steps to configure voice tests:
To do...
Enter system view
Enter NQA test group view
Configure the test type as voice,
and enter test type view
Configure the destination address
of voice probe packets
Configure the destination port of
voice probe packets
Configure the codec type
Configure the advantage factor for
calculating MOS and ICPIF values
Specify the source IP address of
probe packets
Specify the source port number of
probe packets
"Configuring the NQA
Use the command...
system-view
nqa entry admin-name
operation-tag
type voice
destination ip ip-address
destination port port-number
codec-type { g711a | g711u |
g729a }
advantage-factor factor
source ip ip-address
source port port-number
server."
23
Remarks
Required
Required
By default, no destination IP
address is configured for a test
operation.
The destination IP address must be
the same as that of the listening
service on the NQA server.
Required
By default, no destination port
number is configured.
The destination port must be the
same as that of the listening service
on the NQA server.
Optional
By default, the codec type is
G.711 A-law.
Optional
By default, the advantage factor is
0.
Optional
By default, no source IP address is
specified.
The source IP address must be the
IP address of a local interface. The
local interface must be up;
otherwise, no probe packets can
be sent out.
Optional
By default, no source port number
is specified.