2.2.3 Wall Mounting

IP500, IP500 V2 control units and IP500 external expansion modules can be wall mounted. To do this, a wall mounting kit
is required in addition to suitable wall fixings.
In addition to the existing
apply when wall mounting a unit:
· The wall surface must be vertical, flat and vibration free. Attachment to temporary walls is not supported.
· Only the screws provided with the mounting kit should used to attach the brackets to the control unit.
The following wall mounting kits exist.
· IPO IP500 RACK MNTG KIT V3 (SAP Code 700503160)
IPO IP500 RACK MNTG KIT V2 (SAP Code 700500923)
These kits can be used for wall and rack mounting of an IP500 or IP500 V2 control unit and IP500 external
expansion modules. The kits incorporates cable routing at the front and rear of the unit. For wall mounted control
units it allows orientation of the control unit base card slots to the left or to the right.
· IPO IP500 WALL MNTG KIT (SAP Code 700430150)
This old design of wall mounting kit can be used for wall mounting an IP500 or IP500 V2 control units only. It does
not provide any cable routing and requires the control unit to be mounted with the base card slots to the right
only.
IP500/IP500 V2 Installation
IP Office 8.0
environmental requirements
Installation Requirements: Space Requirements
for an IP Office system, the following additional requirements
56