7.6.3 System Shutdown

IP Office systems running IP Office Release 6 can be shut down in order to perform maintenance. The shut down can be
either indefinite or for a set period of time after which the IP Office will automatically reboot.
During the shut down process, the current configuration in the control unit's RAM memory is copied to the control units
non-volatile memory. For IP500 V2 systems that location is the System SD card.
For control units with memory cards the memory cards can be
!
WARNINGS
·
· A shutdown must always be used to switch off the system. Simply removing the power cord or switching off
the power input may cause the loss of configuration data.
· This is not a polite shutdown, any user calls and services in operation will be stopped. Once shutdown, the
system cannot be used to make or receive any calls until restarted.
· The shutdown process takes up to a minute to complete. When shutting down a system with a C110 Unified
Communications Module installed, the shutdown can take up to 3 minutes while the card safely closes all open
files and closes down its operating system. During this period the module's LED 1 remains green.
· When shutdown, the LEDs shown on the system are as follows. Do not remove power from the system or
remove any of the memory cards until the system is in this state:
· LED1 on each IP500 base card installed will also flash red rapidly plus LED 9 if a trunk daughter card
is fitted to the base card.
· The CPU LED on the rear of the system will flash red rapidly.
· The System SD and Optional SD memory card LEDs on the rear of the system are extinguished.
· To restart a system when shutdown indefinitely, or to restart a system before the timed restart, switch power
to the system off and on again.
System Shutdown Using IP Office Manager
1. Using IP Office Manager, select File | Advanced | System Shutdown.
2. Using the Select IP Office menu, the System Shutdown Mode menu is displayed.
3. Select the type of shutdown required. If Indefinite is used, the system can only be restarted by having its power
switched off and then on again. If a Timed shutdown is selected, the IP Office will reboot after the set time has
elapsed.
System Shutdown Using the System Status Application
1. Start
System Status
2. In the navigation panel select System.
3. At the bottom of the screen select Shutdown System.
4. Select the time duration for the shutdown or indefinite.
IP500/IP500 V2 Installation
IP Office 8.0
and access the IP Office's status output.
69
shutdown and restarted
170
15-601042 Issue 25i (03 January 2013)
separately from the system.