Avaya IP500 Installation Manual page 203

Hide thumbs Also See for IP500:
Table of Contents

Advertisement

Ports
Description
AUDIO
3.5mm Stereo jack socket. Used for external music on hold source input.
378
AUX
If pressed during a restart of the control unit, the control unit
157
on the System SD card. If pressed for more than 5 seconds when a system is running, the control unit
will
shutdown
CPU
Indicates the status of the control unit.
· Alternate red/green = Starting up.
· Green on = Okay.
EXPANSION
RJ45 socket. Used for direct connection to external expansion modules using the Expansion Interconnect
384
cable supplied with the expansion module.
EXT O/P
3.5mm Stereo jack socket. Used for switching external relay systems such as door entry controls. The
137
port contains two independent switches controlled by the IP Office.
INPUT
AC power input port.
35
LAN
RJ45 socket. The port is a full-duplex 10/100Mbps auto-sensing, MDI crossover port. With the WAN port
385
forms a managed layer 3 Ethernet switch.
Optional SD
Used for the Optional SD card. The LED is used in the same way as for the System SD (see below).
154
RESET
This switch is used to restart the IP Office, optionally erasing the configuration and or the core software in
145
the process. See
RS232
9-Way D-Type socket. Used for system maintenance.
146
System SD
Used for the System SD card,. The LED is used as follows.
154
· Off =
Card shutdown
· Green on = Card present.
· Green flashing = Card in use.
· Orange steady = Reset imminent.
RJ45 socket. The port is a full-duplex 10/100Mbps auto-sensing, MDI crossover port. With the WAN port
WAN
forms a managed layer 3 Ethernet switch. This port is not supported on systems running in IP Office Basic
385
Edition - PARTNER® Mode, IP Office Basic Edition - Norstar Mode or IP Office Basic Edition - Quick Modes.
Used for connection of a
recommended and for some locales may be a regulatory requirement.
IP500/IP500 V2 Installation
IP Office 8.0
for 10 minutes.
119
Reset Button
.
145
.
170
functional or protective ground
System Components: IP500 V2 Control Unit
skip booting
· Red on = No software.
· Flashing Red = Error/Shutdown.
· Red flashing = Card initializing or shutting down.
· Red fast flashing = card full
· Red steady = Card failure/wrong type.
. Use of a ground for all systems is
91
15-601042 Issue 25i (03 January 2013)
from the /primary folder
157
Page 203

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ip500 v2

Table of Contents