9.7.6 E1R2 PRI Trunk Cards

These cards support E1 trunks with R2 signalling. Each trunk provides up to 30B+D channels.
E1R2 PRI trunk cards are available with either RJ45 or coaxial cable connectors.
E1R2PRI trunk Cards
· These cards include two plastic stand off pillars for installation and a replacement blanking plate for the rear of
IP400 control units.
· For E1R2 coaxial card, a ground-jumper cable and coaxial connector locking rings are included.
· For dual port cards the IP406 V2 only supports a single dual card in Slot A.
· For the IP500 and IP500 V2 control units, an IP500 Carrier Card is required, up to a maximum of 2 IP500 Carrier Cards.
E1R2 coax trunk cards must be grounded correctly and require the IP Office control unit to be connected to a
ground
. Normally the ends of one connection is grounded. For example, if the exchange Tx1 is grounded, the IP Office
39
Rx1 should also be grounded. However this must be confirmed with the line provider to establish which ends they want
grounded.
1. Connect the ground strap spade end (B) supplied with the card to the spade connection on the card and the other end
(C) to the chassis with the long securing screw also supplied with the card.
2. Use the two jumpers supplied with the card, match the ground selection of the line provider. For example, if the line
provider has grounded their Tx1, place a jumper across the two Rx1 pins of jumper block J6.
IP500/IP500 V2 Installation
IP Office 8.0
IP400 PRI 30 E1R2 RJ45
IP400 PRI 60 E1R2 RJ45
IP400 PRI 30 E1R2 COAX
IP400 PRI 60 E1R2 COAX
Country
SAP Code
CALA, Korea, China
700241631
700241649
CALA
700241656
700241664
IP500
IP500
protective
15-601042 Issue 25i (03 January 2013)
V2
Page 246