Function List - Mitsubishi Electric Q66DA-G User Manual

Channel isolated digital-analog converter module
Hide thumbs Also See for Q66DA-G:
Table of Contents

Advertisement

3
SPECIFICATIONS
3.2

Function List

Table3.2 shows the functions of the Q66DA-G.
Item
D/A conversion enable/
• Specifies whether to enable or disable the D/A conversion for each channel.
disable function
• Disabling D/A conversion of unused channels can increase the conversion speed.
• Specifies whether to output the D/A converted value or output the offset value for
D/A output enable/dis-
each channel.
able function
• Regardless of the output enable/disable setting, the conversion speed is "6ms x
number of conversion-enabled channels".
Analog output HOLD/
• The output analog value can be retained when the programmable controller CPU is
CLEAR function
placed in the STOP status or when an error occurs.
Analog output test during
• When CH
programmable controller
controller CPU STOP, the D/A converted analog value is output.
CPU STOP
Warning output function
• A warning is output if a digital input value falls outside the setting range.
• The increase and decrease in analog output values per conversion cycle of one sta-
Rate control function
tion (6ms) can be limited.
• Using this function prevents rapid change of analog output values.
• The resolution mode can be changed according to the application, and a resolution
setting can be selected from 1/4000, 1/12000 and 1/16000.
Resolution mode
• The resolution mode setting is applicable to all channels in block.
• Refer to Section 3.1.1 for the digital input values and maximum resolution in normal
resolution mode and high resolution mode.
• The input range of digital values can be changed to any given range between -32000
Scaling function
and 32000.
• The module can be changed without the system being stopped.
However, if a module in the analog output range extended mode is replaced with a
Online module change
module that does not support the mode, an intelligent function module switch error
occurs.
Table3.2 Function list
Function
Output enable/disable flag (Y1 to Y6) is forced on during programmable
Reference section
Section 3.4.2
Section 3.3.1
Section 3.2.1
Section 3.2.2
Section 3.2.3
Section 3.2.4
Section 3.1.1
Section 4.5
Section 3.2.5
Chapter 7
3
3.2 Function List
1
2
3
4
5
6
7
8
- 8