P Rogramming - RayTek MI3 Operating Instructions Manual

Hide thumbs Also See for MI3:
Table of Contents

Advertisement

14.2 Programming
14.2.1 Parameter Data
Byte
0 to 6
7
8
9
10
11
12, 13
14, 15
16, 17
18, 19
20
21
22
23
24
25
26...39
40...43
44, 45
46, 47
48, 49
50, 51
52, 53
54, 55
56, 57
58
MI3
info@Raytek-Direct.ca
Address
Description
without
offset
Fix
DP-V1 Status1
DP-V1 Status2
DP-V1 Status3
3
Temp. unit
4
Reserved
5
Bottom temp. of output 1
7
Top temp. of output 1
9
Bottom temp. of output 2
11
Top temp. of output 2
13
Source (head) for output-1
14
Type of source for output-1
15
Analog output mode 1
16
Source (head) for output-2
17
Type of source for output-2
18
Analog output mode 2
reserved
reserved
37
Emissivity Head_1
39
Transmissivity Head_1
41
Averaging time Head_1
43
Peak hold time Head_1
45
Valley hold time Head_1
47
Ambient temp. Head_1
49
Setpoint relay Head_1
51
Relay alarm output control Head_1
Format
67=°C, 70=°F
in 0.1°C /°F
in 0.1°C /°F
in 0.1°C /°F
in 0.1°C /°F
head number
73 = I (internal temp.)
84 = T (object temp.)
5 = TCJ
6 = TCK
7 = TCR
8 = TCS
9 = 0...5V
10 = 0...10V
99 = tristate (disabled)
head number
73 = I (internal temp.),
84 = T (object temp.)
0 = 0...20mA
4 = 4...20mA
9 = 0...5V
10 = 0...10V
99 = tristate (disabled)
* 1000 (0.9  900)
* 1000 (1.0  1000)
* 0.1s (1s  10)
* 0.1s (1s  10)
* 0.1s (1s  10)
in °C /°F
in °C /°F
0 = off
1 = target temp.
2 = internal temp.
Rev. F1 05/2013
Profibus
Range
67 or 70
1...8
73 or 84
5...10, 99
default: 9
1...8
73 or 84
0, 4, 9, 10, 99
default: 4
100 ... 1100
100 ... 1000
0 ...9990
0 ...9990
0 ...9990
dev. range min..
max
dev. range min..
max
0, 1 or 2
83
1.800.868.7495

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MI3 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Table of Contents