15-1: : : : Software Version
15-2: : : : Fault Jog( ( ( ( Latest 3 times) ) ) )
1. When the inverter doesn't work normally, the former fault log stored in2.xxxx will be transferred
to 3.xxxx, then, the one in 1.xxxx to 2.xxxx. The present fault will be stored in the blank 1.xxxx.
Thusly, the fault stored in 3.xxxx is the earliest one of the three, while the one 1.xxxx is the latest.
2. Enter 15-2, the fault 1.xxxx will be displayed firstly, press ▲ , you can read 2.xxx → 3.xxx → 1.xxx,
whereas ▼ , the order is 3.xxx → 2.xxx → 1.xxx → 3.xxx.
3. Enter 15-2, the three fault log will be cleared as the reset key is pressed. The log content will
changed to 1.--- , 2.--- , 3.---.
4. E.g. if the fault log content is '1.OCC' which indicates the latest fault is OC-C, and so on.
15-3: : : : Accumulated Operation Time 1 (Hours): 0 – 9999
15-4: : : : Accumulated Operation Time 2 (Hours X 10000): 0 - 27
15-5: : : : Accumulated Operation Time Mode: 0000: Power on time
1. When the operation time is to 9999 as the operation duration 1 is set. The next hour will be carried
to operation duration 2. Meanwhile, the recorded value will be cleared to 0000, and the record
value of operation duration 2 will be 01.
2. Description of operation time selection:
Preset value
0
1
15-6: : : : Reset the factory setting: 1110: Reset the 50Hz factory setting
As 15-6 is set as 1111, the parameter will be reset to factory setting. The max output voltage will
comply with the voltage and frequency (0-01/0-05) on the nameplate of the motor. The output
frequency is 60Hz if the upper frequency limit is not set.
※Note:
Motor parameters (14-0~14-4) will be modified under V/F control mode when reset factory setting.
On the contrary, motor parameters (14-0~14-4) will not be modified under vector control mode
when reset factory setting.
Description
Power on, count the accumulated time.
Inverter operation, count the accumulated operation time
1111: Reset the 60Hz factory setting
1112: Reset PLC program
0001: Operation time