GE VAT200 Quick Start Manual page 38

Table of Contents

Advertisement

3-23
(Center F of Trav)
3-24
(Amplit of Trav)
3-25
(Drop of Trav)
3-26
(Acc T of Trav)
3-27
(Dec T of Trav)
3-28
(Rise Deviated)
3-29
(Lower Deviated)
※ Notes: 1. Energy Saving Mode is available only under Volts/Hz Mode (0-00 = 0002).
4- Digital Display Operation Mode
Function
LCD
Code No.
Display
4-00
(Motor Curr Disp) Motor Current Display Selection
4-01
(Motor Volt Disp)
4-02
(Bus Volt Disp)
4-03
(PLC Status Disp) PLC Status Display Selection
4-04
(Display Scaling)
4-05
(Display Units)
4-06
(PID Feed Disp)
Center Frequency (CF) of
Traverse Run (%)
Amplitude (A) of Traverse Run
(%)
Drop (D) of Traverse Run (%)
Acc Time (AT) of Traverse Run
(Seconds)
Dec Time (DT) of Traverse Run
(Seconds)
Rise (X) Deviated Traverse (%) 0.0 – 20.0
Lower (Y) Deviated Traverse
(%)
Description
Motor Voltage Display Selection
DC Bus Voltage Display
Selection
Custom Units (Line Speed)
Value
Custom Units (Line Speed)
Display Mode
PID Feedback Display Selection
5.00 – 100.00
0.1 – 20.0
0.0 – 50.0
0.5 – 60.0
0.5 – 60.0
0.0 – 20.0
Range/Code
0000: Disable Motor Current Display
0001: Enable Motor Current Display
0000: Disable Motor Voltage Display
0001: Enable Motor Voltage Display
0000: Disable Bus Voltage Display
0001: Enable Bus Voltage Display
0000: Disable PLC Status Display
0001: Enable PLC Status Display
0 - 9999
0000: Drive Output Frequency is
Displayed
0001: Line Speed is Displayed in
Integer (xxxx)
0002: Line Speed is Displayed with
One Decimal Place (xxx.x)
0003: Line Speed is Displayed with
Two Decimal Places (xx.xx)
0004: Line Speed is Displayed with
Three Decimal Places (x.xxx)
0000: Disable PID Feedback Display
0001: Enable PID Feedback Display
4-12
Chapter 4 Software Index
20.00
10.0
0.0
10.0
10.0
10.0
10.0
Factory
Remarks
Setting
0000
*1
0000
*1
0000
*1
0000
*1
1800
*1
0000
*1
0000
*1

Advertisement

Table of Contents
loading