torque is less than the 9-14 setting value.
= 0001 : If there is over torque, the inverter coasts to stop and flashes OL3. it is necessary to press
'RESET' or external terminal to continue to run.
Parameter8-02,03(Multifunction output terminal ) = 05, the output terminal is output over torque signal.
※ Note: Over torque output signal will be output as the parameter 9-12=0001or 0002 when the level and
time are over the range.
Parameter Group 10 – Volts /Hz Pattern Operation Mode
V/F PATTERN Selection
10-0: : : : V/F PATTERN Selection
10-1: : : : Torque boost gain(V/F pattern modulation)% = 0.0 – 30.0%
10-2: : : : Motor no load current(Amps AC)
10-3: : : : Motor rated slip compensation(%)
10-4: : : : Max output frequency(HZ)
10-5: : : : Max output frequency voltage ratio(%)
10-6: : : : Medium frequency(HZ)
10-7: : : : Medium output frequency voltage ratio (%)
10-8: : : : Min output frequency(HZ)
10-9: : : : Min output frequency voltage ratio (%)
1. 10-0=18, set the V/F pattern freely complying with 10-4~10-9 (Refer to following diagram)
10-5
(Vmax)
10-7
(Vmid)
10-9
(Vmin)
-------------
(V)
%
10-8
10-6
= 0 – 18
= 0.0 – 100.0%
= 0.20 – 650.0Hz
= 0.0 – 100.0%
= 0.10 –650.0Hz
= 0.0 – 100.0%
= 0.10 –650.0Hz
= 0.0 – 100.0%
10-4
650
4-46
Chapter 4 Software Index
Hz