Default Level
2: System level
Parameters
1: 1 stop bit.
1.5: 1.5 stop bits.
2: 2 stop bits.
Description
Use the stopbits command to set the stop bits.
Use the undo stopbits command to restore the default.
By default, the stop bit is one.
NOTE:
The WX series access controllers do not support the stop bits of 1.5.
The command is only applicable to asynchronous serial interfaces (including AUX and
console ports).
The stop bits setting on the terminal must be the same as that on the device user interface for
communication.
Examples
Set the stop bits to 1.5.
<Sysname> system-view
[Sysname] user-interface aux 0
[Sysname-ui-aux0] stopbits 1.5

terminal type

Syntax
terminal type { ansi | vt100 }
undo terminal type
View
User interface view
Default Level
2: System level
Parameters
ansi: Specifies the terminal display type as ANSI.