free user-interface

Syntax
free user-interface { num1 | { aux | console | vty } num2 }
View
User view
Default Level
3: Manage level
Parameters
num1: Absolute number of a user interface, typically starting from 0
num2: Relative number of a user interface, in the following rules:
For the AUX port, the value is 0.
For the console port, the value is 0.
For VTY user interfaces, the value ranges from 0 to 4.
Description
Use the free user-interface command to disconnect with the specified user interface.
You cannot use this command to terminate your own connection.
Examples
Terminate the connection with user interface VTY 1.
<Sysname> free user-interface vty 1
Are you sure to free user-interface vty1? [Y/N]:y
<Sysname>
// If you want to make configurations without interruption from the user using VTY 1, you
can release the connection established on VTY 1.

history-command max-size

Syntax
history-command max-size size-value
undo history-command max-size
View
User interface view
Default Level
2: System level
86