H3C WX Series Command Reference Manual page 174

Hide thumbs Also See for WX Series:
Table of Contents

Advertisement

Description
Use the header command to create a banner.
Use the undo header command to clear a banner.
Examples
Configure banners.
<Sysname> system-view
[Sysname] header incoming %
Input banner text, and quit with the character '%'.
Welcome to incoming(header incoming)%
[Sysname] header legal %
Input banner text, and quit with the character '%'.
Welcome to legal (header legal)%
[Sysname] header login %
Input banner text, and quit with the character '%'.
Welcome to login(header login)%
[Sysname] header motd %
Input banner text, and quit with the character '%'.
Welcome to motd(header motd)%
[Sysname] header shell %
Input banner text, and quit with the character '%'.
Welcome to shell(header shell)%
NOTE:
The character % is the starting/ending character of text in this example. Entering % after
the displayed text quits the header command.
As the starting and ending character, % is not a part of a banner.
Test the configuration remotely using Telnet. (only when login authentication is
configured can the login banner be displayed).
**************************************************************************
* All rights reserved (2004-2006)
* Without the owner's prior written consent,
* no decompiling or reverse-engineering shall be allowed.
**************************************************************************
Welcome to legal(header legal)
Press Y or ENTER to continue, N to exit.
Welcome to motd(header motd)
Welcome to login(header login)
Login authentication
174
*
*
*