System-Failure; Temperature-Limit - H3C WX Series Command Reference Manual

Hide thumbs Also See for WX Series:
Table of Contents

Advertisement

system-failure

Syntax
system-failure { maintain | reboot }
undo system-failure { maintain | reboot }
View
System view
Default Level
3: Manage level
Parameters
maintain: Specifies that when the system detects any software abnormality, it maintains
the current situation, and does not take any measure to recover itself.
reboot: Specifies that when the system detects any software abnormality, it recovers
itself through automatic reboot.
Description
Use the system-failure command to configure the exception handling method.
By default, the system adopts the reboot method to handle exceptions.
Examples
Set the exception handling method to reboot.
<Sysname> system-view
[Sysname] system-failure reboot

temperature-limit

Syntax
temperature-limit slot-number lower-value upper-value
undo temperature-limit slot-number
View
System view
Default Level
2: System level
Parameters
slot-number: Slot number.
lower-value: Lower temperature limit in Celsius degrees. The value ranges from 0 to 70.
155